Skip to content

Toilet flange rough in?

  • by

A toilet flange is a pipe fitting that is used to connect a toilet to the drain pipe. The flange is installed over the top of the drain pipe and is held in place with screws. The flange has a hole in the center that allows the toilet to be connected to the drain pipe.

Roughing in a toilet flange is the process of installing the drainpipe and flange that will connect the toilet to the sewer line. This is typically done before the actual toilet is installed, as it can be difficult to do after the toilet is in place.

Should toilet flange sit on subfloor?

When installing a toilet, it is best practice to install the flange on top of the finished floor. If the flange is installed flush with the finished floor, or even below the finished floor, leak paths can form because the flange won’t be at the correct height to accept the horn at the bottom of the toilet.

The standard distance from the back wall for a toilet flange is 12 inches, or 12-1/2 inches from the center of the flange to the wall framing. This is to allow for the thickness of the drywall, which is 1/2 inch thick. Therefore, the plumber should set the toilet flange at least 15-1/2 inches from the center of the flange to the wall framing.

See also  Niagara conservation toilet keeps running?

Does toilet flange sit on concrete or tile

The toilet flange needs to be on top of the finished floor, meaning the bottom edge of the flange should be on the same plane as the toilet. So if your toilet sits on the tile, the flange needs to be on top of the tile too.

The flange is the part of the toilet that bolts to the floor. Make sure that it is properly fastened down before proceeding. It is also a good idea to “dry fit” the toilet (set it in place without attaching it) to make sure that it does not rock. If it does rock, use shims to prevent rocking. Just tightening the bolts probably will not stop the rocking but will risk cracking the toilet or breaking the flange.

What size hole needs to be cut for a toilet flange?

A standard size flange pipe can have a diameter of either 3 or 4 inches, depending on the size of the waste line. A 4-inch hole works in both cases. Plumbers cut it with a hole saw or a reciprocating saw.

Caulk is a substance used to seal gaps or cracks, and it can be very effective in preventing water from getting into areas where it shouldn’t be. In the case of a toilet, caulking around the base can help to keep water from seeping underneath and causing a foul smell or other problems.

Is 1 2 inch too high for toilet flange?

The proper toilet flange height is when it’s flush with the top of the finished floor. The optimum height is about ¼ inch. It’s easier to get your flange flush with the floor if you lay your flooring before you install the flange.

See also  How to sublimate on toilet paper?

This toilet flange is designed to glue on the inside of the pipe or expand inside the pipe. Leave the old toilet flange right in place and glue on the new one at the right elevation for the floor, if it’s plastic. The flange should be sitting with the bottom edge flush with the top of the floor.

How do I know if my toilet is a 10 or 12 rough

If the old toilet is still there, measure from the center of the capped bolts (on the bottom) to the wall (not the baseboard). There should be 24 inches of clearance from the wall facing the bowl and 15 inches on each side as a guideline. If your measurements are between 115 and 125 inches, it is a 12-inch rough-in.

Toilet flanges are the small, round pieces that connect the toilet to the floor drain. The optimum flange height is 1/4 inch above the finished floor. This typically allows for almost any type of wax ring to be used and still ensure a good seal.

Do you have to screw the toilet flange to concrete floor?

You need to use a concrete drill bit that is slightly smaller than the screws. The number of screws you need will depend on the size of the flange. Most flanges require four screws to hold them in place.

If you’re attaching a new toilet flange to your subfloor, you’ll need to use either wood screws or cement screws, depending on the material of your subfloor. Simply slide the toilet flange bolts into the new flange and secure them with washers and nuts. There’s no need to use an adhesive when installing a gasket-sealed PVC flange.

See also  Instaprivy portable toilet?

Does floating floor go under toilet flange

If you’re installing a new laminate floor, pedestal sink, and toilet, you should install the laminate flooring first so it’s under the sink and toilet. Because laminate flooring floats above the sub-floor on top of underlayment, it will expand and contract slightly with the temperature and humidity of the room. This can cause gaps to form between the laminate and the walls, so it’s best to install it first to avoid any problems.

The tools needed for this repair are an electric drill or screwdriver used to screw the flange into the pilot hole in the tile, a hammer to tap the flange into place, and a putty knife to apply the caulk.

How do you secure a toilet flange to the floor?

You will need to use some sort of adhesive in order to glue the flange to the pipe. You can use either cement or contact adhesive.

Closet bolts, also known as toilet bolts or T-bolts, are used to secure the flange to the flooring. They come in a range of sizes, with the most common being 1/4″ or 5/16″. Standard T-bolt length is 2-1/4″, but extra-long bolts are available for when you need to go through multiple or thick layers of flooring.

Final Words

A toilet flange rough in is the distance from the wall to the center of the drain pipe.

There are a few things to keep in mind when doing a toilet flange rough in. First, make sure that the flange is level and flush with the floor. Second, make sure that the flange is the correct size for the toilet. Third, make sure that the flange is mounted securely to the floor. Fourth, make sure that the flange is properly sealed. If the flange is not level, flush with the floor, the correct size, mounted securely, or sealed properly, it could cause problems with the toilet.